Vitesse TOF ICP-MS | Nu Instruments
TOF-ICP-MS delivers exceptional speed and elemental coverage, analysing nearly the entire periodic table thousands of times per second. It enables multi-element analysis of complex samples—even when you don’t know what you’re looking for.

Product Details
Vitesse is a time-of-flight inductively coupled plasma mass spectrometer that has been purpose designed to be the ultimate tool for high speed multi-element applications such as laser ablation imaging and nanoparticle analysis.
- Fastest wide mass range data acquisition for applications such as laser ablation imaging and nanoparticle analysis.
- High sensitivity to probe micron sized trace element features in solid samples and determine the elemental composition of individual nanoparticles.
- High analyte selectivity with a segmented reaction cell optimised for multi-element analysis.
- High physical resolving power Time-of-Flight (TOF) mass spectrometer to give interference free analysis.
- Unique quad, cell, TOF option (QCT) for the ultimate flexibility in removing interferences.
- High speed conventional ICP-MS analysis is also possible with a range of sample accessory devices.
- Additional flexibility is available with an optional full size quadrupole before the reaction cell to improve the selectivity of the chemistries being used to remove difficult interferences.

Solutions
Laser Ablation
The Vitesse TOF-ICP-MS is fully compatible with leading laser ablation platforms, enabling seamless integration into existing laboratory workflows. Native software connectivity supports both ESI (Elemental Scientific Lasers) and Teledyne CETAC laser ablation systems, allowing for synchronized control, streamlined method setup, and efficient data acquisition. This tight integration ensures reliable performance and maximizes productivity across a wide range of applications.

Solutions
Single & Nano Particle
The Vitesse TOF-ICP-MS is ideally suited for single particle analysis, leveraging its true multi-element detection capability to capture complete particle composition—an advantage not possible with traditional quadrupole systems that measure one element at a time. Its high-speed data acquisition enables precise characterization of individual particles using the standard sample introduction system, without the need for specialized hardware. For further performance gains, the system is fully compatible with a range of commercially available spray chambers and nebulizers, allowing users to optimize sensitivity and throughput for demanding applications.
Benefits
Markets & Applications
Geological
ICP-TOF enables simultaneous multi-element analysis, providing a complete elemental fingerprint of geological samples in a single measurement.
Environmental
With full-spectrum capture, ICP-TOF delivers comprehensive monitoring of complex environmental samples, including water, soil, and aerosols.
Biomedical
ICP-TOF provides detailed multi-element insights into biological systems, supporting research in areas such as metal homeostasis and nanoparticle interactions.